Oracle8 Error Messages
Release 8.0

A54625_01

Library

Product

Contents

Prev Next

31
Oracle Performance Manager Messages

VMM-01000 to VMM-01999: Not So Critical Error Messages

VMM-01000: Failed to create chart.

Cause: A window handle for a chart could not be obtained.

Action: Try freeing up resources, such as closing other windows.

VMM-01001: Collection name not valid.

Cause: The data collection name you have chosen contained invalid characters.

Action: Use only valid characters: A-Z, a-z, 0-9, _, -, and $.

VMM-01002: System failed to allocate a timer.

Cause: A timer from the system could not be obtained.

Action: Try closing other applications which use timers.

VMM-01003: Failed to connect to database.

Cause: A database session could not be opened.

Action: Specify a different username, password, or connect string.

VMM-01004: Failed to connect to Trace database.

Cause: A Trace database session could not be opened.

Action: Check Trace username, password, and connect string.

VMM-01005: No name specified for data collection.

Cause: You failed to specify a name for the data collection file.

Action: Specify a name in the Data Collection Name dialog box when requested.

VMM-01006: Error during initialization for recording.

Cause: One of the initialization steps for recording failed.

Action: Verify the setup of the environment (such as directory structures).

VMM-01007: The chart should not be modified during recording.

Cause: You tried to modify a chart during recording.

Action: Do not modify a chart during recording.

VMM-01008: The window should not be modified during recording.

Cause: You tried to modify a window during recording.

Action: Do not modify a window during recording.

VMM-01009: Please stop recording before closing window.

Cause: You tried to close a window during recording.

Action: Do not close a window during recording.

VMM-01010: Cannot connect to Oracle Parallel Server.

Cause: Cannot run "OPS Select" statement to determine if it is in OPS mode.

Action: Install Parallel Server scripts.

VMM-02000 to VMM-02999: Informational Messages

VMM-02000: Query returned no rows.

Cause: No rows were returned when the query was executed.

Action: None, unless you know the query should return data. In that case, report the problem to Oracle Worldwide Customer Support.

VMM-02001: No data available.

Cause: A query did not return any data.

Action: Execute the query using SQL*Plus or a similar tool to verify that data can be returned.

VMM-02002: The 'Name' cannot be null or contain all spaces.

Cause: Name field validation failed.

Action: Enter a valid name in the Name field.

VMM-02003: Please enter a valid SQL statement that returns data.

Cause: SQL statement validation failed. To create a chart, you must enter a valid SQL statement that returns data.

Action: Enter a valid SQL statement that returns data.

VMM-02004: Increasing polling interval to allow for query completion.

Cause: Query execution time was longer than the polling interval.

Action: Increase the polling interval.

VMM-02005: Please select a chart to add.

Cause: A chart was not added because none was selected.

Action: Select a chart to add.

VMM-02006: Please select a chart to remove.

Cause: A chart was not removed because none was selected.

Action: Select a chart to remove.

VMM-02007: Please select a window.

Cause: Window field validation failed.

Action: Select a window.

VMM-02008: Please add one or more charts to the 'Selected Charts' list.

Cause: Window field validation failed.

Action: Add one or more charts to the Selected Charts list.

VMM-02009: Please enter a number.

Cause: Window field validation failed.

Action: Enter a number.

VMM-02010: Save changes to Oracle Performance Manager?

Cause: You selected the Exit command before saving changes.

Action: Select YES to save changes, NO to abandon changes or CANCEL to not exit.

VMM-02011: 'Password' must be specified.

Cause: Password field validation failed.

Action: Enter a password in the appropriate field.

VMM-02012: 'Label' must be specified.

Cause: Label field validation failed.

Action: Enter a label in the appropriate field.

VMM-02013: The first 'Function' field must be specified.

Cause: Function1 field validation failed.

Action: Select function desired.

VMM-02014: The first 'Column' field must be specified.

Cause: Column1 field validation failed.

Action: Select column desired.

VMM-02015: Simple operation must be selected for non-numeric data.

Cause: A non-numeric operation validation failed.

Action: Select the Simple radio button, or numeric columns only.

VMM-02016: The 'Operation' field must be supplied.

Cause: Operation field validation failed.

Action: Select operation desired.

VMM-02017: The second 'Function' field must be specified.

Cause: Function2 field validation failed.

Action: Select function desired.

VMM-02018: The second 'Column' field must be specified.

Cause: Column2 field validation failed.

Action: Select column desired.

VMM-02019: Please choose a selection in the 'Selections to Display' list.

Cause: Failed to delete selection because none was specified.

Action: Choose selection to delete.

VMM-02020: 'Table' chart type must be selected for non-numeric data.

Cause: Type field validation failed.

Action: Select Table type, or numeric columns only.

VMM-02021: Cannot transpose axes for non-numeric data.

Cause: Transpose axes validation failed.

Action: Select the No radio button, or numeric columns only.

VMM-02022: No function can be applied to non-numeric data.

Cause: Non-numeric function validation failed.

Action: Select <none> for function, or numeric columns only.

VMM-02023: Please add function and column selection.

Cause: Selection list validation failed.

Action: Select function and column desired.

VMM-02032: No user-defined charts available for loading.

Cause: You attempted to load charts from a repository that does not contain any saved charts.

Action: Connect to a repository that contains the charts you want to load.

VMM-02034: Do you wish to load charts? Note that this will close all active windows and replace user-defined objects.

Cause: You are attempting to load charts.

Action: Loading charts overrides currently loaded user-defined charts and windows. Before loading charts, you can save currently loaded charts for future use, or you may want to connect to a different repository.

VMM-02041: Please select an entity first.

Cause: An entity has not been selected.

Action: Select an entity using "File.Change SNMP Entity..." menu item.

VMM-02042: Please select a window name first.

Cause: A window name has not been selected.

Action: Select a window name using "Window Name" combo-box.




Prev

Next
Oracle
Copyright © 1997 Oracle Corporation.

All Rights Reserved.

Library

Product

Contents